Bsk Km Ukca NF Wireless Smoke Detectors En14604 Interlinked Smoke Alarms for Scotland
Technical Specifications: Details of the product function:
Basic Info.
Model NO. | TSS380D-HR |
Installation Method | Ceiling Mounting |
Certificate | CE, Bsi, NF, Ukca, Red, RoHS, Reach, ISO9001, BSCI |
Produce Life Time | >10 Years |
Specification | White |
Trademark | JBE |
Origin | Zhejiang, China |
Production Capacity | 100000 Piece/Month |
Product Description
Technical Specifications:
Power Source | DC 3V battery | Low Voltage Threshold | ≤2.6V |
Operation Current | ≤8uA | Hush time | 8minutes |
Alarm Sensitivity | 0.10 - 0.16dB/m | Product service life | >10 years |
Comply with standard | EN 14604:2005/AC:2008 | Humidity Range | < 93% relative humidity (RH) |
Alarm Current | ≤60mA | Temperature Range | 0ºC to 40ºC |
Alarm Volume | >85dB(A) @ 3 meters. | Size | 120mm in diameter x 36.6mm depth |
Sound Pattern | (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern) |
Details of the product function:
Standby mode | After the product is installed, if the smoke alarm device operate properly, the red LED flashes once every 48 seconds |
Alarm mode | When the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappeared |
Low battery mode | When the battery voltage bleow threshold, the red LED will flash once every 48 seconds with a sound of "chrip" |
Fault mode | If the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 48 seconds |
Silence mode | Press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds |
Non disturb mode | When the alarm device is in low battery mode, in order to avoid disturbing your at night, Please press the test button for 3 seconds which will mute this warning tone for about 14 hours. The red LED will flash once every 48 seconds during No disturb mode. |
Test mode | Test the unit to ensure operate properly by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released |
NOTE | WEEKLY TESTING IS REQUIRED |